Replacing a 1970s UL962A test stand with an end-of-line tester that keeps records.

ClientA leading electrical appliance manufacturer with plants worldwide
IndustryElectrical appliances · UL962A compliance testing
ScopeAutomated HiPot and continuity testing for multi-circuit assemblies; operator UI; result logging
DeliveredPiloted in 2022 · now 50+ stations worldwide

The problem

The client's UL962A compliance tester was built in the 1970s. It lacked modern features, was getting more expensive to keep running every year, and — worst of all — recorded nothing: no information about the test process and no record of results.

What we built

  • Barcode-driven test selection — scan the part, the station loads the right test.
  • HiPot and continuity testing across every circuit of the assembly.
  • Live socket map showing each circuit's status as it tests.
  • Pass/fail tallies per shift, and every result stored against the serial.
  • Self-validation — the tester checks itself, so a bad reading points at the part, not the station.

The result

From a 2022 pilot to 50+ stations worldwide. Every station confirms the operator is running the correct test, tracks each operation and every pass/fail, and validates itself — so the plant has accountability and a record for every part, where the 1970s tester had none.

End-of-line electrical tester screen with live socket map and pass/fail tallies
The delivered tester's operator screen.

Running a test stand older than your engineers?

Talk about your test system